Foster FTCG-1 is industrial diaphragm natural gas meter with wireless communication functionality for industrial and commercial application
MAIN FEATURE
12 safe shut-off functions.
Daily transmit meter data to server.
Remotely lock/unlock meter through software.
Wirelessly transmit and confirm the prepayment to meter.
Time-of-use pricing and / or dynamic pricing.
Shut-off valve when flow rate continuously beyond 1.2 Qmax and transmit data to server.
Shut-off or lock valve when non-usage of gas for 30 days and transmit data to server.
Temperature conversion optional.
Ladder pricing optional.
Shut-off valve when meter was influenced by magnetic interference and transmit data to server.
Lock valve when magnetic interference reached above 5 times and transmit data to server.
Remote smart gas control system mainly consists of three parts: the hardware part of data acquisition, the network transmission part and the software processing part. Collecting the data acquisition module in part collect the data from gas meter by a certain communication protocol method; Data is based on GPRS/CDMA/3G network, and sent that to Data Monitoring Center; Data Center can use computer communication, information management and database system to real-time monitoring the gas meter’s working status on customer sides. This system not only can collect real-time data (including the flow, temperature, pressure and other information), but also can carry out real-time information monitoring, data analysis and statistics. It also can remote charge and control gas meter. It can adjust price for multi-tier pricing mechanism. And it also can alarm when the smart gas meter has abnormal information
PARAMETERS
Model |
G6 |
G10 |
G16 |
G25 |
G40 |
|
Norminal flow rate Qn(m3/h) |
6 |
10 |
16 |
25 |
40 |
|
Maximum flow rate Qmax(m3/h) |
10 |
16 |
25 |
40 |
65 |
|
Minimum flow rate Qmin(m3/h) |
0.06 |
0.1 |
0.16 |
0.25 |
0.4 |
|
Starting flow rate Qst(dm3/h) |
8 |
13 |
13 |
20 |
32 |
|
Overload flow rate Qr(m3/h) |
12.0 |
19.2 |
30 |
48 |
78 |
|
Error of indication |
Qmin ≤ Q<0.1Qmax,±2.4% |
|||||
Cyclic volume(dm3) |
4 |
10 |
20 |
|||
Maximum working pressure |
0.5 bar |
|||||
Pressure absorption(Pa) |
≤ 300 |
|||||
Durability |
run the meter at Qmax for 5000h |
|||||
Working temperature range |
-10℃~+40℃ |
|||||
Storage temperature range |
-20℃~+60℃ |