Ultrasonic water meter

  • Ultrasonic heat meter R100 USMH
  • Ultrasonic heat meter R100 USMH
Ultrasonic heat meter R100 USMHUltrasonic heat meter R100 USMH

Ultrasonic heat meter R100 USMH

  • Model: USMH
  • Type: Ultrasonic heat meter
  • Accuracy ratio: Class D/R250
  • Body material :Brass
  • Product description: Ultrasonic heat meter R100 USMH
  • INQUIRY   EMAIL

FOSTER USHM is Ultrasonic heat meter uses solid-state technology in acompact, which measure and display heat energy when water through the heat exchange system

WORKING PRINCIPLE:

When the water through the heat meter which installed in the heat exchange system, then meter’s calculator calculates and display the release or absorption of heat energy according to flow quantity from the flow sensor and the temp. signal of Inlet and Return flow from matching temp. sensors, and the water flow through time,the formula is like this:

In the formula:Q means the release heat quantity from the medium kJ;
Qm means the reheat liquid instantaneous mass flow quantity through the heat meter kg/s;
∆h means the specific enthalpy difference of heat carrying liquid from inlet temperature and outlet temperature in the heat transfer loop kJ/kg;
T means the Times

MAIN FEATURES:

No moving parts permitting the most reliable and longer term life; lowest pressure loss;
Adopt imported precision electronics components, high measurement accuracy, low power consumption,good stability
No dirt deposited dead angle, no impurities by the medium, chemical material and the interference of magnetic materials
Using in wide range, both for cold and hot
USHM is available with a wired lead from M-bus or RS 485, also it could be connect by wireless AMR/AMI endpoints through LoRa
Long battery life that support free maintenance up to 10 years
The meter can be installed using horizontal or vertical piping, USHM will not measure flow when an “empty pipe” condition

DIMENSION:


Dn15

Dn20

Dn25

Dn32

Dn40

L

110

130

160

160

200

H

85

95

105

105

115

W

85

85

85

85

85








PARAMETERS:

Size

mm

Dn15

Dn20

Dn25

Dn32

Dn40

Body Length

mm

110

130

160

180

180

Qmax

m3/h

1500

2000

3500

6000

10000

Qt

l/h

24

32

56

96

160

Qmin

l/h

15

20

35

60

100

Measuring ratio

1:100

1:100

1:100

1:100

1:100

Installation position

Horizontal and Vertical

Max, Reading

m3

999999,99

Max, Reading

KW.H

99999999

Pressure Loss

ΔP

ΔP<20 at Q3

Max, Pressure

MAP

PN16

Temperature range

5~95

Temperature difference

K

3~90

Climate and EMC Class

(E1,M1) (B)

Display digits

8 digits LCD

Temperature sensor

PT1000

Default communication

Mbus/Rs485 (LoRa as optional)

Battery life

10 years (8 years for wireless application)


Inquiry

Scan the qr codeClose